Search results for "bone quality"

showing 10 items of 13 documents

In vitro comparison of primary stability of two implant designs in D3 bone

2016

Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…

02 engineering and technologyIn Vitro Techniques03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral DentistryOrthodonticsDental Implantsbusiness.industryResearchSignificant differenceImplant designDental Implantation Endosseous030206 dentistry021001 nanoscience & nanotechnologyImplant stability quotient:CIENCIAS MÉDICAS [UNESCO]Denture RetentionResonance frequency analysisOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgery0210 nano-technologybusiness
researchProduct

Influence of short implants geometry on primary stability.

2018

Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…

0206 medical engineeringDentistry02 engineering and technologyBone and BonesDental Prosthesis Retention03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral Dentistrybusiness.industryResearchDental Implantation Endosseousfood and beverages030206 dentistry:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringShort implantsOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgerybusiness
researchProduct

A topological look at human trabecular bone tissue

2017

Bone quality is affected by trabecular architecture at microscopic level. Various abnormalities of bone tissue lead to altered strength and to an increased susceptibility to fracture, such as Osteoporosis and Osteoarthritis, two major health burdens of our society. These are two complex musculoskeletal diseases that mainly concern bone tissue. In the last twenty years, there has been a growing interest in finding an appropriate topological model for the micro-architecture of trabecular bone tissue. In particular, we prove that these models involve general topological spaces. The appropriate notion to deal with is that of CW-complex.

0301 basic medicineStatistics and ProbabilityPathologymedicine.medical_specialtyTrabecular bone tissueOsteoporosis030209 endocrinology & metabolismOsteoarthritisTopological spaceBone tissueTopologyGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineCW-complexBone DensityBone qualityHumansMedicineGeneral Immunology and Microbiologybusiness.industryApplied MathematicsMicroscopic levelGeneral MedicineAnatomyTrabecular architecturemedicine.diseaseTrabecular bone030104 developmental biologymedicine.anatomical_structureModeling and SimulationCW-complex; Euler characteristic; trabecular bone tissue; Kelvin cellCancellous BoneEuler characteristicSettore MAT/03 - GeometriaGeneral Agricultural and Biological SciencesbusinessKelvin cell
researchProduct

Influence of the structural components of artificial turf systems on impact attenuation in amateur football players

2019

AbstractThe purpose of this research was to evaluate the influence of the structural components of different 3rd generation artificial turf football field systems on the biomechanical response of impact attenuation in amateur football players. A total of 12 amateur football players (24.3 ± 3.7 years, 73.5 ± 5.5 kg, 178.3 ± 4.1 cm and 13.7 ± 4.3 years of sport experience) were evaluated on three third generation artificial turf systems (ATS) with different structural components. ATS were composed of asphalt sub-base and 45 mm of fibre height with (ATS1) and without (ATS2) elastic layer or compacted granular sub-base, 60 mm of fibre height without elastic layer (ATS3). Two triaxial accelerome…

AdultMale0301 basic medicineAccelerationPoison controlSTRIDElcsh:MedicineFútbolArticleLower energyRunningYoung Adult03 medical and health sciences0302 clinical medicineFloors and FloorcoveringsSoccerArtificial turfHumanslcsh:ScienceMathematicsOrthodonticsEsportsFootball playersMultidisciplinaryAttenuationlcsh:RDeporteBone quality and biomechanicsBiomechanical Phenomena030104 developmental biologyRisk factorsAthletesFootball fieldSuperficies deportivas sintéticaslcsh:QEducació físicaAmateur030217 neurology & neurosurgeryInstalación deportiva
researchProduct

Bone quality in the midpalate for temporary anchorage devices.

2009

Objective The aim of the present study was to quantitatively assess the bone quality of the palatal bone from an implantologic standpoint. Material and methods The material consisted of palatal tissue blocks of autopsy material from 22 subjects (19 male, three female), between 18 and 63 years of age. The specimens comprised the anterior part of median palate (APMP) from about 7 mm behind the incisive foramen (first premolar regions), the middle part of median palate (MPMP, second premolar region), and the posterior part of the median palate (PPMP, first molar region). They were prepared in the transversal plane using ground-thin-section technology. The midpalatal areas of the different part…

AdultMalePalate HardYounger ageBone densityAdolescentDentistryHard tissueMandibular first molarYoung AdultBone DensityBone Marrowparasitic diseasesBone qualityPremolarmedicineCadaverOrthodontic Anchorage ProceduresHumansIncisive foramenDental Implantsbusiness.industryAge FactorsCranial SuturesMiddle Agedmedicine.anatomical_structureFemaleOral SurgerybusinessBone volumeClinical oral implants research
researchProduct

Running in highly cushioned shoes increases leg stiffness and amplifies impact loading

2018

AbstractRunning shoe cushioning has become a standard method for managing impact loading and consequent injuries due to running. However, despite decades of shoe technology developments and the fact that shoes have become increasingly cushioned, aimed to ease the impact on runners’ legs, running injuries have not decreased. To better understand the shoe cushioning paradox, we examined impact loading and the spring-like mechanics of running in a conventional control running shoe and a highly cushioned maximalist shoe at two training speeds, 10 and 14.5 km/h. We found that highly cushioned maximalist shoes alter spring-like running mechanics and amplify rather than attenuate impact loading. T…

AdultMalemusculoskeletal diseasesrasitusvammatComputer sciencelcsh:MedicineHEEL STRIKEMASSbone quality and biomechanicsurheilujalkineetArticlejuoksuGROUND REACTION FORCES03 medical and health sciences0302 clinical medicineotorhinolaryngologic diseasesHumans315 Sport and fitness sciencesGround reaction forcelcsh:ScienceHeel strikeWORKLeg stiffnessLegMultidisciplinaryRunning injuriesbusiness.industryWork (physics)lcsh:Rtechnology industry and agricultureCushioning030229 sport sciencesStructural engineeringShoesbody regionsMECHANICSRUNNERSImpact loadingLoading rateINJURIESlcsh:Qbiomekaniikkabusiness030217 neurology & neurosurgeryScientific Reports
researchProduct

Meta-analysis on the survival of short implants

2010

Objective: To evaluate the success and failure rates of short implants (10 mm or less) for oral rehabilitations in cases of limited bone height. Study Design: Review of the articles published on the topic between the years 2000 and 2010, and development of a descriptive meta-analysis of the results. Results: The majority of the studies obtain a cumulative success rate (CSR) similar to that of longer implants (92.5% - 98.42% for machined and rough-surface implants, respectively). The studies that record lower cumulative success rates (CSR) are later studies that analyze implants with a machined surface. Almost none of the studi-es compared the success/failure rates with the bone quality or l…

Dental Implantsmedicine.medical_specialtybusiness.industryClinical study designDentistry:CIENCIAS MÉDICAS [UNESCO]SurgeryShort implantsMachined surfaceOtorhinolaryngologyDental Prosthesis DesignMeta-analysisMaxillaBone qualityUNESCO::CIENCIAS MÉDICASmedicineHumansSurgeryImplantDental Restoration FailureBone heightbusinessGeneral Dentistry
researchProduct

Relation between bone density and primary implant stability

2010

Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was obs…

Insertion torqueAdultMaleBone densityDentistryOsseointegrationBone DensityOsseointegrationHounsfield scaleBone qualityMedicineHumansGeneral DentistryAgedOrthodonticsDental Implantsbusiness.industryMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Resonance frequency analysisOtorhinolaryngologyJawTorqueUNESCO::CIENCIAS MÉDICASSurgeryFemaleTomographyImplantbusiness
researchProduct

Relation between bone quality values from ultrasound transmission velocity and implant stability parameters--an ex vivo study.

2011

Aim The objective of this study was to determine the relationship between bone qualities measured by ultrasound transmission velocity (UTV) and primary implant stability parameters measured by radiofrequency analysis (RFA) and push-out test (POT) in an ex-vivo model. Materials and methods Three blocks of fresh porcine bone samples were obtained from different anatomic regions, correlating to cortical, mixed and cancellous bone. Mechanical bone qualities of these samples were measured using UTV (expressed in m/s) prior to implantation. Three similar implants (4.1 × 11 mm, AstraTech OS) were inserted into each of the procured bone blocks. The evaluation of implant-bone interface stability was…

Materials scienceRadio WavesSwineDentistryIn Vitro TechniquesDental Prosthesis RetentionIliumImplants ExperimentalPorcine boneBone qualitymedicineAnimalsUltrasonographyDental ImplantsTibiabusiness.industryUltrasoundDental Implantation EndosseousImplant stability quotientmedicine.anatomical_structureModels AnimalImplantOral SurgerybusinessCancellous boneEx vivoBiomedical engineeringClinical oral implants research
researchProduct

Post extractive implant: evaluation of the critical aspects

2017

Purpose Nowadays, implant supported prosthetic rehabilitation is a reliable procedure to replace compromised or untreatable teeth. The purpose of this review is to explore the concept of post extractive implant and the indications for clinical practice through an analysis of recent studies in the literature. All the main factors that could influence the outcome of this treatment will also be considered. Materials and methods Focusing on the extraction-socket healing time, three different implant insertion protocols have been defined: Immediate implant placement (IIP), Early implant placement (EIP), Delayed implant placement (DIP). The entity of bone remodeling can be associated with differe…

Post extractive implantsRehabilitationBone remodeling; Implant stability; Post extractive implants; Dentistry (all)Prosthetic rehabilitationbusiness.industrymedicine.medical_treatmentPlatform switchingDentistrySoft tissue030206 dentistryReviewImplant stabilityBone remodelingOral hygieneOsseointegration03 medical and health sciences0302 clinical medicinePost extractive implantBone qualitymedicineDentistry (all)ImplantbusinessGeneral Dentistry030215 immunology
researchProduct