Search results for "bone quality"
showing 10 items of 13 documents
In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
Influence of short implants geometry on primary stability.
2018
Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…
A topological look at human trabecular bone tissue
2017
Bone quality is affected by trabecular architecture at microscopic level. Various abnormalities of bone tissue lead to altered strength and to an increased susceptibility to fracture, such as Osteoporosis and Osteoarthritis, two major health burdens of our society. These are two complex musculoskeletal diseases that mainly concern bone tissue. In the last twenty years, there has been a growing interest in finding an appropriate topological model for the micro-architecture of trabecular bone tissue. In particular, we prove that these models involve general topological spaces. The appropriate notion to deal with is that of CW-complex.
Influence of the structural components of artificial turf systems on impact attenuation in amateur football players
2019
AbstractThe purpose of this research was to evaluate the influence of the structural components of different 3rd generation artificial turf football field systems on the biomechanical response of impact attenuation in amateur football players. A total of 12 amateur football players (24.3 ± 3.7 years, 73.5 ± 5.5 kg, 178.3 ± 4.1 cm and 13.7 ± 4.3 years of sport experience) were evaluated on three third generation artificial turf systems (ATS) with different structural components. ATS were composed of asphalt sub-base and 45 mm of fibre height with (ATS1) and without (ATS2) elastic layer or compacted granular sub-base, 60 mm of fibre height without elastic layer (ATS3). Two triaxial accelerome…
Bone quality in the midpalate for temporary anchorage devices.
2009
Objective The aim of the present study was to quantitatively assess the bone quality of the palatal bone from an implantologic standpoint. Material and methods The material consisted of palatal tissue blocks of autopsy material from 22 subjects (19 male, three female), between 18 and 63 years of age. The specimens comprised the anterior part of median palate (APMP) from about 7 mm behind the incisive foramen (first premolar regions), the middle part of median palate (MPMP, second premolar region), and the posterior part of the median palate (PPMP, first molar region). They were prepared in the transversal plane using ground-thin-section technology. The midpalatal areas of the different part…
Running in highly cushioned shoes increases leg stiffness and amplifies impact loading
2018
AbstractRunning shoe cushioning has become a standard method for managing impact loading and consequent injuries due to running. However, despite decades of shoe technology developments and the fact that shoes have become increasingly cushioned, aimed to ease the impact on runners’ legs, running injuries have not decreased. To better understand the shoe cushioning paradox, we examined impact loading and the spring-like mechanics of running in a conventional control running shoe and a highly cushioned maximalist shoe at two training speeds, 10 and 14.5 km/h. We found that highly cushioned maximalist shoes alter spring-like running mechanics and amplify rather than attenuate impact loading. T…
Meta-analysis on the survival of short implants
2010
Objective: To evaluate the success and failure rates of short implants (10 mm or less) for oral rehabilitations in cases of limited bone height. Study Design: Review of the articles published on the topic between the years 2000 and 2010, and development of a descriptive meta-analysis of the results. Results: The majority of the studies obtain a cumulative success rate (CSR) similar to that of longer implants (92.5% - 98.42% for machined and rough-surface implants, respectively). The studies that record lower cumulative success rates (CSR) are later studies that analyze implants with a machined surface. Almost none of the studi-es compared the success/failure rates with the bone quality or l…
Relation between bone density and primary implant stability
2010
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was obs…
Relation between bone quality values from ultrasound transmission velocity and implant stability parameters--an ex vivo study.
2011
Aim The objective of this study was to determine the relationship between bone qualities measured by ultrasound transmission velocity (UTV) and primary implant stability parameters measured by radiofrequency analysis (RFA) and push-out test (POT) in an ex-vivo model. Materials and methods Three blocks of fresh porcine bone samples were obtained from different anatomic regions, correlating to cortical, mixed and cancellous bone. Mechanical bone qualities of these samples were measured using UTV (expressed in m/s) prior to implantation. Three similar implants (4.1 × 11 mm, AstraTech OS) were inserted into each of the procured bone blocks. The evaluation of implant-bone interface stability was…
Post extractive implant: evaluation of the critical aspects
2017
Purpose Nowadays, implant supported prosthetic rehabilitation is a reliable procedure to replace compromised or untreatable teeth. The purpose of this review is to explore the concept of post extractive implant and the indications for clinical practice through an analysis of recent studies in the literature. All the main factors that could influence the outcome of this treatment will also be considered. Materials and methods Focusing on the extraction-socket healing time, three different implant insertion protocols have been defined: Immediate implant placement (IIP), Early implant placement (EIP), Delayed implant placement (DIP). The entity of bone remodeling can be associated with differe…